Votre panier

Votre panier est vide.

Votre panier est vide.

Continuer le magasinage

RECHERCHE RAPIDE DE VÉHICULE

RECHERCHE VÉHICULE

Utilisateur

Raymond Kazmierczak

À rejoins en date due:

Jan. 29, 2013

Points

1200

Commentaire(s)

7

Questions votée(s)

0

Réponses votée(s)

1

Votes positifs

0

Votes contre

1

Votes reçus

4

Votes négatifs reçus

0

picto contact

Vous cherchez nos meilleurs participants ?

Voir les utilisateurs
picto contact

Vous n'avez pas trouvé ce que vous cherchiez ?

Posez une question

0

Smart Entry Warning

2020 Honda Accord Push-Start EVO-ONE 3x Lock Start installed, works perfectly. Set up to shut-down on door opening to stop Smart Entry Warning however Smart-Entry Warning still displaying on screen. Set Unit for Door Shutdown, 3x Lock Start, Push Start. Any help would be appreciated.

0

Ram Promaster City

Flashers run continuously when vehicles remote started. Has OEM alarm, wired as such.

0

2005 Cadillac DHS

EVO-ALL wont see data on OBD, checked and re-soldered connection, still nothing. Am I correct in assuming I need the MASTER KEY, customer gave me a aftermarket made key. Or am I missing something else?

0

Does d2d option have to be selected for evo-all to work with avital 4113 r/s?

I installed an avital 4113 r/s in a 2013 Honda accord. It starts once then doesn't start again. After reviewingmy programming options, do I have to select d2d mode in flash link in order for it to talk to the r/s?

0

2013 Honda Accord Will Start once, then not start again.

2013 Honda Accord Key Start Vehicle will start once however wont shutdown by brake, or unlock doors with R/S Remote. After killing remote start, attempting to start again gets 5 Parking LIght Flashes and wont start again unless I unplug R/S brain box. I have made all connections according to 14661, programmed correctly and did Encryptor through Flashlink.

1

EVo won't bypass key unless purple white wire grounded for split second

2012 Ford Edge 80bit key. Installed viper smart start and remote start. Had to do w2w because of smart start module interfering with Evo-all. Car starts in d2d mode without smart start module. When in w2w I have to ground purple/white wire for one second after initialization and release before it starts. Now the guide mentions grounding unlock wire and hooking another unlock wire to purple white but that doesn't work. Any ideas?

1

Vehicle shuts down when connected to smart start module

I have the settings adjusted to only the options shown, however the vehicle shuts off after a few minutes as opposed to 15 like I have set above in the options menu. When I remove the smart start module the vehicle will run perfectly. If it helps, when the smart start is in line, the locks lock and unlock. I grounded the brown wire as detailed in the pdf file, could you look at my firmware history and tell me what settings I have wrong? Thank you

1

Can a EVO-ALL Standalone Starter and Smart Start work together?

I have a 2013 Ford Edge SA Key. I installed an EVO-ALL as a standalone starter. Im trying to add the Smart Start Module and will NOT communicate. I want the 3xLock to work as well as the smart start module. Is this possible? Ive spent the better part of the weekend working on it and cannot get it to work for the customer. Thank you in advance. Ive tried every setting in the FLASHLINK. Ive tried cutting and grounding every wire on the smart start. No communication between the two and I remember speaking with someone at FORTIN and they said a EVO-ALL will not work 3x start and and additional remote start. Does this apply to the Smart Start as well?

1

2013 Ford Edge key start not starting

Wired up to directed 5x03, when attempting to remote start, red light constant blue light flickers on then off. Does not attempt remote start. Brain box clicks once then retries. Any ideas?? Does the same when wired in standalone except dash lights come on like accessory is on.

0

2007 Compass Wont Start-Up in EVO Stand-alone mode

Installed EVO-ALL as standalone. wired according to FORTIN wiring diagram. Vehicle will not start with 3xLock. If If I hook yellow black up to door sensor, it will start when the door opens, and shut off when door closes? Thinking I have the wrong external input. Any ideas?

No results

picto contact

Vous cherchez nos meilleurs participants ?

Voir les utilisateurs
picto contact

Vous n'avez pas trouvé ce que vous cherchiez ?

Posez une question

Support Technique

Recherchez parmi nos produits les plus populaires et les sujets d'installation disponibles dans notre section Questions et réponses.

En savoir plus
Téléchargez notre application de guides de dépannage étape par étape disponible pour iOS et Android ou parcourez notre version de bureau.

En savoir plus
Accédez à la plus grande base de données de schémas de câblage et de photos en ligne de l'industrie. Un jeton gratuit est fourni dans chaque boîte EVO-SERIES.

En savoir plus
Vous n'avez pas trouvé l'information que vous cherchiez ? Posez-nous une question en remplissant le formulaire de demande de support technique. Un spécialiste produit vous répondra sous peu.

En savoir plus
Des solutions de contrôle à distance et de connectivité à la fine pointe de la technologie au soutien technique haut de gamme, découvrez pourquoi vous devriez choisir les produits Fortin.

En savoir plus

Ce site Web utilise des cookies pour vous garantir la meilleure expérience utilisateur. En poursuivant votre navigation sur notre site, vous acceptez notre utilisation des cookies. En savoir plus Continuer